Related Experiment Video
Updated: Oct 6, 2025

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Effects of wall compliance and light-curing protocol on wall deflection of simulated cavities in bulk-fill composite
1One-Stop Specialty Center, Seoul National University Dental Hospital, Seoul, South Korea.
Background/Purpose:
Cuspal deflections in composite restoration have been investigated with considering wall compliance of human tooth cavity and light-curing protocol. The purpose of this study was to investigate effects of mold wall compliance and radiant emittance of LED light on the wall deflection of simulated aluminum mold cavities restored with a bulk-fill composite.
Materials And Methods:
Sixty aluminum molds simulating a class II mesio-occluso-distal (MOD) cavity (6 W × 8 L × 4 D mm; W, width; L, length; D, Depth) were prepared and allocated to three groups with varying mold wall thicknesses of 1, 2, and 3 mm. The molds were bulk-filled with a bulk-fill composite and photo-cured. Four light-curing protocols were used: three duty ratios/exposure times: 100%/20 s, 50%/40 s, or an increasing mode (0 → 100%)/40 s with a pulse width modulated (PWM) LED curing light and one 20 s exposure time with a commercial LED light.
Results:
Mean mold wall deflection at 2000 s decreased with increasing mold wall thickness (1, 2, and 3 mm) (p < 0.05). Wall deflections with 1- and 2-mm-thick molds exhibited no statistically significant differences among light-curing protocols (p > 0.05). However, in the 3-mm-thick mold, wall deflections with low radiant emittance were significantly lower than those with high radiant emittance (p < 0.05).
Conclusion:
In composite restoration of class II MOD cavities, lowering the radiant emittance of LED light can reduce the mold wall deflection only in low compliance cavities.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Masonry Cavity Walls
Maintaining a clean cavity during construction...
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Accelerated Curing of Concrete