Related Experiment Video
Updated: Oct 6, 2025

Detection of 3-Nitrotyrosine in Atmospheric Environments via a High-performance Liquid Chromatography-electrochemical Detector System
Published on: January 30, 2019
Application of a novel nylon needle filter-based solid-phase extraction device to determination of 1-hydroxypyrene in
Shi-Wen Yue1, Yi-Lian Zhou1, Xi-Tian Peng2
1Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Wuhan University of Science and Technology, Wuhan, P. R. China.
Abstract:
In this work, a simple and miniaturized solid-phase extraction device was constructed by connecting a commercial nylon needle filter to a syringe, which was applied for extracting 1-hydroxypyrene from a urine sample via hydrophobic and hydrogen bond interactions. The nylon membrane in the needle filter acted as the solid-phase extraction adsorbent, meanwhile, it filtered the particles in the urine sample. To obtain high extraction efficiency, key parameters influencing extraction recovery were investigated. The entire pretreatment process was accomplished within 5 min under the optimal conditions. By coupling high-performance liquid chromatography-ultraviolet, a rapid, low-cost, and convenient nylon needle filter-based method was established for the analysis of 1-hydroxypyrene in a complex urine matrix. Within the linearity range of 0.2-1000 μg/L, the method exhibited a satisfactory correlation coefficient (R = 0.9999). The limit of detection was 0.06 μg/L, and the recoveries from urine sample spiked with three concentrations (5, 20, and 100 μg/L) ranged from 105.8% to 113.1% with the relative standard deviations less than 6.7% (intra-day, n = 6) and 8.9% (inter-day, n = 4). Finally, the proposed method was successfully applied for detecting 1-hydroxypyrene in urine samples from college students, smokers, gas station workers, and chip factory workers. The detected concentration in actual urine samples ranged from 0.46 to 5.26 μg/L. Taken together, this simple and cost-effective nylon needle filter-based solid-phase extraction device showed an excellent application potential for pretreating hydrophobic analytes from aqueous samples.
More Related Videos
08:41Integration of Miniaturized Solid Phase Extraction and LC-MS/MS Detection of 3-Nitrotyrosine in Human Urine for Clinical Applications
Published on: July 14, 2017
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018