Observational study of changes in utilization and outcomes in mechanical ventilation in COVID-19
Christian Karagiannidis1, Corinna Hentschker2, Michael Westhoff3,4
1Department of Pneumology and Critical Care Medicine, Cologne-Merheim Hospital, ARDS and ECMO Center, Kliniken der Stadt Köln, Witten/Herdecke University Hospital, Cologne, Germany.
Background:
The role of non-invasive ventilation (NIV) in severe COVID-19 remains a matter of debate. Therefore, the utilization and outcome of NIV in COVID-19 in an unbiased cohort was determined.
Aim:
The aim was to provide a detailed account of hospitalized COVID-19 patients requiring non-invasive ventilation during their hospital stay. Furthermore, differences of patients treated with NIV between the first and second wave are explored.
Methods:
Confirmed COVID-19 cases of claims data of the Local Health Care Funds with non-invasive and/or invasive mechanical ventilation (MV) in the spring and autumn pandemic period in 2020 were comparable analysed.
Results:
Nationwide cohort of 17.023 cases (median/IQR age 71/61-80 years, 64% male) 7235 (42.5%) patients primarily received IMV without NIV, 4469 (26.3%) patients received NIV without subsequent intubation, and 3472 (20.4%) patients had NIV failure (NIV-F), defined by subsequent endotracheal intubation. The proportion of patients who received invasive MV decreased from 75% to 37% during the second period. Accordingly, the proportion of patients with NIV exclusively increased from 9% to 30%, and those failing NIV increased from 9% to 23%. Median length of hospital stay decreased from 26 to 21 days, and duration of MV decreased from 11.9 to 7.3 days. The NIV failure rate decreased from 49% to 43%. Overall mortality increased from 51% versus 54%. Mortality was 44% with NIV-only, 54% with IMV and 66% with NIV-F with mortality rates steadily increasing from 62% in early NIV-F (day 1) to 72% in late NIV-F (>4 days).
Conclusions:
Utilization of NIV rapidly increased during the autumn period, which was associated with a reduced duration of MV, but not with overall mortality. High NIV-F rates are associated with increased mortality, particularly in late NIV-F.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: