Related Experiment Video
Updated: Oct 6, 2025

Fluorescent Leakage Assay to Investigate Membrane Destabilization by Cell-Penetrating Peptide
Published on: December 19, 2020
Ratiometric fluorescent detection of lead ions in aquatic environment and living cells using a fluorescent
Pramod Kumar Mehta1, Jongyong Jeon1, Ki Ryu1
1Research Center for Controlling Intercellular Communication and Education and Research Center for Smart Energy Materials and Process, Department of Chemistry and Chemical Engineering, Inha University, Incheon 402-751, South Korea.
Abstract:
Ratiometric fluorescent detection using dual emission bands is highly necessary to quantify Pb(II) in aquatic environment and live cells. We synthesized a ratiometric fluorescent peptidyl probe (1) by conjugation of a peptide receptor for Pb(II) with an excimer-forming benzothiazolylcyanovinylene fluorophore. The peptidyl probe dissolved well in aqueous solution and displayed an emission band at 538 nm (λex = 460 nm). Upon addition of Pb(II) (0-20 μM), the emission maximum shifted from 538 nm to 575 nm and the emission intensity ratio (I575 /I538) increased significantly from 0.40 to 2.26. 1 exhibited a selective ratiometric response to Pb(II) over other metal ions. 1 with a low detection limit (1.2 ppb) of Pb(II) detected nanomolar concentrations (0-500 nM) of Pb(II) ions in groundwater and tap water. The cell-permeable probe detected intracellular Pb(II) by ratiometric fluorescent images. The binding mode study using NMR, IR and CD spectroscopy, and TEM revealed that the probe formed a 1:1 complex with Pb(II) and then formed red-emissive nanoparticles and fibrils. The probe exhibited desirable detection properties such as ratiometric detection, high solubility in water, visible light excitation, high selectivity and sensitivity for Pb(II), cell-permeability, and rapid response (< 6 min).
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Photoluminescence: Applications