Related Experiment Video
Updated: Oct 6, 2025

Single-Molecule Tracking Microscopy - A Tool for Determining the Diffusive States of Cytosolic Molecules
Published on: September 5, 2019
Taylor-Aris methodology for the experimental determination of molecular diffusion coefficients: Tutorial with focus
Donatela Sadriaj1, Gert Desmet2, Deirdre Cabooter3
1KU Leuven, Department for Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, Herestraat 49, Leuven, Belgium; Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, 1050 Brussel, Belgium.
Abstract:
High-Performance Liquid Chromatography (HPLC) is a key technique in the evaluation of biopharmaceuticals. To improve the separation of biopharmaceuticals, it is crucial to improve the fundamental understanding of the parameters governing their band broadening behavior. This can be obtained by a detailed assessment of the individual contributions to their mass transfer. For this purpose, a precise knowledge of the molecular diffusion coefficient (Dm) of biopharmaceuticals is required. Only little experimental data is available for the Dm-values of biopharmaceuticals under HPLC relevant conditions. Furthermore, none of the available equations that can be used to calculate Dm-values, allows to account for any conformational changes that might occur. The Taylor-Aris method is a very simple and absolute method that is often employed to determine Dm-coefficients. The Taylor-Aris method measures the band broadening of an analyte in an open tube under laminar conditions, wherein (1) longitudinal diffusion can be ignored, (2) the sample is fully radially equilibrated and (3) the contribution of the extra-column variance to the total variance is negligible. Moreover, since the open tubes are typically coiled for practical reasons, (4) the influence of secondary flows on the band broadening should be insignificant. In this tutorial paper, the impact of the four conditions mentioned above on the accuracy of the obtained Dm values is revisited. For this purpose, Dm values are measured for two representative compounds (Bovine Serum Albumin and Thiourea), and the obtained values are compared with literature data and theoretical recommendations. Based on these observations, a set of 'rules' for accurate and fast Dm measurements is put forward. Finally, an Interactive Tool (IT), combining these rules in a comprehensive way, is introduced and can be used to set up TA experiments.
More Related Videos
06:55Synthesis of Cyclic Polymers and Characterization of Their Diffusive Motion in the Melt State at the Single Molecule Level
Published on: September 26, 2016
06:34In Situ Monitoring of Diffusion of Guest Molecules in Porous Media Using Electron Paramagnetic Resonance Imaging
Published on: September 2, 2016
Related Concept Videos
Protein Diffusion in the Membrane
Passive Diffusion: Overview and Kinetics
When administered orally, drugs establish a substantial concentration gradient between the gastrointestinal (GI) lumen and the bloodstream, expediting...
Dialysis
Theories of Dissolution: Diffusion Layer Model
This process starts with a thin layer, saturated with the drug, forming at the interface between the solid and liquid. The solute then diffuses from this layer into the main solution. The Noyes-Whitney equation suggests that the rate of dissolution relies on the diffusion...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Diffusion