Paradoxical Thromboembolic Ischemic Stroke Following Tissue Plasminogen Activator Instillation for Clogged Central
Ifeanyi Nwosu1, Emeka Ibeson1, Sehajpreet Singh1
1Internal Medicine, Maimonides Medical Center, New York, USA.
Central venous catheters including dialysis catheters are a potential source of venous thrombosis and pose a risk for paradoxical embolic events including ischemic stroke and systemic embolism in patients with a patent foramen ovale (PFO). The adult population with a PFO and patients with a central venous dialysis catheter (CVDC) are at increased risk of a paradoxical embolic event. Since bubble study is not routinely done during echocardiogram in a patient with CVDC, it is difficult to identify at-risk patients for paradoxical embolic events during catheter manipulation, especially for clogged CVDC. We report a rare case of a 79-year-old lady with end-stage renal disease on hemodialysis (HD) using a CVDC who developed a paradoxical embolic ischemic stroke following the use of tissue plasminogen activator (tPA) for unclogging a dialysis catheter. We aimed to highlight the existing risks of thromboembolism associated with the long-term use of central CVDC, especially the potential risk of paradoxical embolism and ischemic stroke with the use of tPA for management of clogged dialysis catheters. We emphasize the questionable need for a bubble study echocardiogram in all patients requiring long-term dialysis catheters.
Central venous catheters including dialysis catheters are a potential source of venous thrombosis and pose a risk for paradoxical embolic events including ischemic stroke and systemic embolism in patients with a patent foramen ovale (PFO). The adult population with a PFO and patients with a central venous dialysis catheter (CVDC) are at increased risk of a paradoxical embolic event. Since bubble study is not routinely done during echocardiogram in a patient with CVDC, it is difficult to identify at-risk patients for paradoxical embolic events during catheter manipulation, especially for clogged CVDC. We report a rare case of a 79-year-old lady with end-stage renal disease on hemodialysis (HD) using a CVDC who developed a paradoxical embolic ischemic stroke following the use of tissue plasminogen activator (tPA) for unclogging a dialysis catheter. We aimed to highlight the existing risks of thromboembolism associated with the long-term use of central CVDC, especially the potential risk of paradoxical embolism and ischemic stroke with the use of tPA for management of clogged dialysis catheters. We emphasize the questionable need for a bubble study echocardiogram in all patients requiring long-term dialysis catheters.
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Venous Thrombosis I: Introduction
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management
Venous Thrombosis IV: Nursing Management
Hemodialysis I: Introduction