Related Experiment Video
Updated: Jun 12, 2026

Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research
Published on: January 12, 2013
T1D -weighted ihMT imaging - Part I. Isolation of long- and short-T1D components by T1D -filtering
Andreea Hertanu1,2, Lucas Soustelle1,2, Arnaud Le Troter1,2
1Aix Marseille Univ, CNRS, CRMBM, Marseille, France.
Purpose:
To identify T1D -filtering methods, which can specifically isolate various ranges of T1D components as they may be sensitive to different microstructural properties.
Methods:
Modified Bloch-Provotorov equations describing a bi-T1D component biophysical model were used to simulate the inhomogeneous magnetization transfer (ihMT) signal from ihMTRAGE sequences at high RF power and low duty-cycle with different switching time values for the dual saturation experiment: Δt = 0.0, 0.8, 1.6, and 3.2 ms. Simulations were compared with experimental signals on the brain gray and white matter tissues of healthy mice at 7T.
Results:
The lengthening of Δt created ihMT high-pass T1D -filters, which efficiently eliminated the signal from T1D components shorter than 1 ms, while partially attenuating that of longer components (≥ 1 ms). Subtraction of ihMTR images obtained with Δt = 0.0 ms and Δt = 0.8 ms generated a new ihMT band-pass T1D -filter isolating short-T1D components in the 100-µs to 1-ms range. Simulated ihMTR values in central nervous system tissues were confirmed experimentally.
Conclusion:
Long- and short-T1D components were successfully isolated with high RF power and low duty-cycle ihMT filters in the healthy mouse brain. Future studies should investigate the various T1D -range microstructural correlations in in vivo tissues.
Related Concept Videos
Type I Diabetes I: Introduction
Type II Diabetes I: Introduction