A Silicon-tipped Fiber-optic Sensing Platform with High Resolution and Fast Response
Published on: January 7, 2019
Fast-Response Oxygen Optical Fiber Sensor based on PEA2 SnI4 Perovskite with Extremely Low Limit of Detection
Shunshuo Cai1, Yangyang Ju2, Yangming Wang2
1Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China.
Abstract:
Oxygen sensor is an important technique in various applications including industrial process control, medical equipment, biological fabrication, etc. The reported optical fiber-based configurations so far, using gas-sensitive coating do not meet the stringent performance targets, such as fast response time and low limit of detection (LOD). Tin-based halide perovskites are sensitive to oxygen with potential use for sensor applications. Here, the halide perovskite-based oxygen optical fiber sensor by combining phenylethylammonium tin iodide (PEA2 SnI4 ) and tilted fiber Bragg grating (TFBG) is demonstrated. The PEA2 SnI4 -based oxygen optical fiber sensor is reversible at room temperature with a response time of about 10 s, and the experimental LOD approaches to an extremely low oxygen concentration of about 50 ppm. The as-fabricated oxygen sensor shows a relative response change of 0.6 dB for an oxygen concentration increase from 50 ppm to 5% with good gas selection against NO2 , CO, CO2 , H2 . This work extends the sensor applications of halide perovskites, providing a novel technique for rapid and repeatable oxygen gas detection at a low level.