David Hana1, Tyler Miller1, Paulina Skaff2
1Department of Medicine, West Virginia University School of Medicine, Morgantown, WV 26506, USA.
Background:
Pre-procedural chronic kidney disease (CKD) and in-hospital acute kidney injury (AKI) are associated with worse outcomes following transcatheter aortic valve replacement (TAVR). We tested the feasibility of reducing overall AKI by avoiding pre-procedural cardiac CT angiography (CCTA) by using direct 3D-TEE guidance in TAVR patients with known CKD.
Methods:
An institutional TAVR database was examined from January 2016 to June 2020 to identify 396 patients in whom CCTA sizing was performed and 54 patients with creatinine (Cr) of >1.6 mg/dL in whom direct 3D-TEE, without prior CCTA, was used for TAVR guidance. Baseline demographics, procedural, echocardiographic, and clinical endpoints were compared as defined by the Valve Academic Research Consortium-2 criteria.
Results:
Baseline demographics and risk factors were similar in both groups other than the creatinine level in CCTA vs. TEE groups (1.33 ± 1.1 vs 1.76 ± 0.7 mg/dL, p = 0.005). Procedural contrast volume was significantly lower in the TEE group compared to the CCTA group. No differences were noted in echocardiographic and clinical endpoints for both groups. Despite higher baseline Cr, patents in the TEE group experienced a similar pattern of changes in Cr compared to the CCTA group, with an overall renal improvement noted at the time of discharge for both groups.
Conclusions:
In patients with baseline CKD, careful avoidance of large contrast loads associated with CCTA and intra-procedural aortography by using TEE guidance may help reduce AKI following TAVR.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Imaging Studies VII: Vascular Imaging
Aortic Regurgitation III: Medical Management