A capaciflector provides continuous and accurate respiratory rate monitoring for patients at rest and during exercise
Related Experiment Video
Updated: Oct 6, 2025

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Nick Hayward1, Mahdi Shaban2, James Badger3
1Perioperative & Critical Care Theme, Southampton NIHR Biomedical Research Centre, University Hospital Southampton / University of Southampton, Southampton, UK. nickhayward@doctors.org.uk.
Abstract:
Respiratory rate (RR) is a marker of critical illness, but during hospital care, RR is often inaccurately measured. The capaciflector is a novel sensor that is small, inexpensive, and flexible, thus it has the potential to provide a single-use, real-time RR monitoring device. We evaluated the accuracy of continuous RR measurements by capaciflector hardware both at rest and during exercise. Continuous RR measurements were made with capaciflectors at four chest locations. In healthy subjects (n = 20), RR was compared with strain gauge chest belt recordings during timed breathing and two different body positions at rest. In patients undertaking routine cardiopulmonary exercise testing (CPET, n = 50), RR was compared with pneumotachometer recordings. Comparative RR measurement bias and limits of agreement were calculated and presented in Bland-Altman plots. The capaciflector was shown to provide continuous RR measurements with a bias less than 1 breath per minute (BPM) across four chest locations. Accuracy and continuity of monitoring were upheld even during vigorous CPET exercise, often with narrower limits of agreement than those reported for comparable technologies. We provide a unique clinical demonstration of the capaciflector as an accurate breathing monitor, which may have the potential to become a simple and affordable medical device.Clinical trial number: NCT03832205 https://clinicaltrials.gov/ct2/show/NCT03832205 registered February 6th, 2019.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Respiratory Volumes and Capacities I
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...