A simple embed over encryption scheme for DICOM images using Bülban Map
Related Experiment Video
Updated: Oct 6, 2025

3D Scanning Technology Bridging Microcircuits and Macroscale Brain Images in 3D Novel Embedding Overlapping Protocol
Published on: May 12, 2019
Veerappan Manikandan1, Rengarajan Amirtharajan2
1School of Electrical & Electronics Engineering, SASTRA Deemed University, Thanjavur, 613 401, India.
Abstract:
With the onset of any pandemic, the medical image database is bound to increase. These medical images are prone to attack by hackers for their medical data and patient health information. To safeguard these medical images, a new algorithm is proposed. The algorithm involves secretly embedding the patient identification number into the medical image and encrypting the medical image, protecting the patient's identity and the patient's medical condition from hackers. The encryption algorithm involved a single stage of confusion and two stages of diffusion. The confusion operation was performed using the key generated by the Bülban map. The first stage of diffusion was done in the transform domain, using 5/3 transformation. The second diffusion stage was performed in the spatial domain by altering the pixel values using the key. The algorithm was tested on over 30 DICOM (Digital Imaging and Communications in Medicine) images taken from Open Science Framework (OSF), a public database for COVID-19 patients. The algorithm could resist the statistical attacks upon analysis, providing a PSNR of 7.084 dB and entropy of 15.9815 bits for the cipher image. The correlation coefficients for the cipher image were 0.0275, -0.0027, 0.018 in horizontal, vertical and diagonal directions. The keyspace was 2((M-1) ×N)×16, with M the number of rows and N the number of columns in the image. The key sensitivity was high. The test results and metric analysis prove that the algorithm is an effective one for embedding and encryption.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies VII: Vascular Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...