Measurement of strain in the rod for lumbar pedicle screw fixation: An experimental and finite element study
Masud Rana1, Jayanta Kumar Biswas1,2, Sandipan Roy3
1Department of Aerospace Engineering & Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur, West Bengal, 711103, India.
Abstract:
Spinal fusion with pedicle-screw-rod is being used widely for treating spinal deformities diseases. Several biomechanical studies on screw rod based implant failure through screw pullout, bending, screw breakage have been performed. But few studies are available regarding the effect of strain for breakage of rod. So, the purpose of the present study is to observe strain at the rod connected with the pedicle screw for different loading condition. The strain in stainless steel (SS) connecting rods for pedicle screw fixation were measured using strain gauge. In order to investigate the bio-mechanical response of lumbar spine with reference to strain in the rod, a simple experimental setup was developed using a specimen of L1-S spine segment. SS rods were used for pedicle screw implant on prototyped lumbar Spine. Prior to testing with pedicle screw, the lumbar spine specimen was also compared with FE results. The strain measured using strain gauges at L3-L4 level on SS rod were within a range of 85 to 310 microstrain under 6, 8, 10 Nm flexion and extension, and for L4-L5 level, these values were within a range of 95 to 440 microstrain. It was found that FE result was higher than the strain gauge result and the error varied between 10.5% to 33% with average error of 22.8%. However similar stain behavior was observed by the FE analysis. The proposed method, as well as the qualitative data, might be helpful for the researchers to understand biomechanical behavior of pedicle-screw implanted spine.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
11:28A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Related Concept Videos
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Normal Strain under Axial Loading
Temperature Dependent Deformation
Measurements of Strain
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Strain Energy
Consider a rod that is fixed at one end and subjected to an axial force at the free end. This axial force induces stress within the rod, leading to its elongation. As the axial force increases, so does the elongation of the rod, illustrating a direct relationship between the force applied and the resulting...