Related Experiment Video
Updated: Oct 6, 2025

Treatment of Platelet Products with Riboflavin and UV Light: Effectiveness Against High Titer Bacterial Contamination
Published on: August 24, 2015
Exploring the Causes of Wastage of Blood and Its Components in a Tertiary Care Hospital Blood Bank
Farrah Bashir1, Attika Khalid2,3, Shahbaz Iqbal4
1Pediatric Oncology, Combined Military Hospital, Rawalpindi, PAK.
Background Blood donated by healthy people is extremely important as it is integral in emergent situations. The authors aimed to address and highlight the main causes of the wastage of donated blood and its components. Methodology A cross-sectional study was conducted at a blood bank of a tertiary care center between January 2019 and March 2020. All the information regarding blood donated and blood components during the study period was documented on a predefined proforma. The blood bags which were seropositive, reached their shelf-life expiry, expired due to non-utilization, or quantity was non-sufficient were discarded. Blood showing any changes of either hemolysis or turbidity was also discarded. Other reasons for discarding blood units included leakage (damage to or fault in the blood bag), hemolytic reasons, or miscellaneous reasons. Results A total of 9308 blood donations were received as donations during the study period. Out of the total donations, 7,988 (85.8%) were subjected for component formation including red cell component (RCC), fresh frozen plasma (FFP), and platelets. A total of 23,964 components were prepared using the donated blood. Out of these 2128 (8.87%) units were discarded. Upon stratifying the discarded blood according to the type of component, it was found that platelets made up 1148 (53.9%) units, red cell component composed 324 (15.2%) units, and fresh frozen plasma composed 313 (14.7%) units of discarded blood. Seropositive was reported to be 32.3%. Of this, the red cell component made up 276 (85.2%) units. Conclusion The present study reported a discard rate of 8.87%. Of these, the majority was composed of platelets due to the shortest shelf life. Leakage of blood bags remained a predominant cause for the discard of blood components. Seropositivity for hepatitis B, C, and human immunodeficiency virus (HIV) was reported in almost 30% units of donated blood. Further large-scale studies should be conducted to reassess how wastage of donated blood can be minimized.
Background Blood donated by healthy people is extremely important as it is integral in emergent situations. The authors aimed to address and highlight the main causes of the wastage of donated blood and its components. Methodology A cross-sectional study was conducted at a blood bank of a tertiary care center between January 2019 and March 2020. All the information regarding blood donated and blood components during the study period was documented on a predefined proforma. The blood bags which were seropositive, reached their shelf-life expiry, expired due to non-utilization, or quantity was non-sufficient were discarded. Blood showing any changes of either hemolysis or turbidity was also discarded. Other reasons for discarding blood units included leakage (damage to or fault in the blood bag), hemolytic reasons, or miscellaneous reasons. Results A total of 9308 blood donations were received as donations during the study period. Out of the total donations, 7,988 (85.8%) were subjected for component formation including red cell component (RCC), fresh frozen plasma (FFP), and platelets. A total of 23,964 components were prepared using the donated blood. Out of these 2128 (8.87%) units were discarded. Upon stratifying the discarded blood according to the type of component, it was found that platelets made up 1148 (53.9%) units, red cell component composed 324 (15.2%) units, and fresh frozen plasma composed 313 (14.7%) units of discarded blood. Seropositive was reported to be 32.3%. Of this, the red cell component made up 276 (85.2%) units. Conclusion The present study reported a discard rate of 8.87%. Of these, the majority was composed of platelets due to the shortest shelf life. Leakage of blood bags remained a predominant cause for the discard of blood components. Seropositivity for hepatitis B, C, and human immunodeficiency virus (HIV) was reported in almost 30% units of donated blood. Further large-scale studies should be conducted to reassess how wastage of donated blood can be minimized.
More Related Videos
10:25Microfluidic Flow Chambers Using Reconstituted Blood to Model Hemostasis and Platelet Transfusion In Vitro
Published on: March 19, 2016
05:23Continuous Manual Exchange Transfusion for Patients with Sickle Cell Disease: An Efficient Method to Avoid Iron Overload
Published on: March 14, 2017
Related Concept Videos
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Errors occurring during blood pressure monitoring
Several factors...
Disorders of Hemostasis
Thromboembolic Disorders
Two factors primarily cause thromboembolic conditions.
Tertiary Healthcare System
Disorders of Erythrocytes
Erythrocyte disorders can be broadly categorized into two main types: anemic and polycythemic conditions.
A low oxygen-carrying capacity of the blood due to the loss, lower production, or destruction of erythrocytes is termed anemia. Hemorrhagic anemia, for example, occurs when bleeding from an external wound or internal ulcer reduces erythrocyte counts.
On the other...