Background:
Prolonged mechanical ventilation in preterm infants may cause complications. We aimed to analyze the variables affecting extubation outcomes in preterm infants at high risk of extubation failure.
Methods:
This was a single-center, observational, retrospective study. Extubation failure was defined as survival with the need for reintubation within 72 h. Successfully extubated neonates (group 1) were compared to those with failed extubation (group 2). Multivariate logistic regression analysis evaluated factors that predicted extubation outcomes.
Results:
Eighty infants with a birth weight under 1000 g and/or gestational age (GA) under 28 weeks were included. Extubation failure occurred in 29 (36.2%) and success in 51 (63.8%) neonates. Most failures (75.9%) occurred within 24 h. Pre-extubation inspired oxygen fraction (FiO2) of 27% had a sensitivity of 58.6% and specificity of 64.7% for extubation failure. Post-extubation FiO2 of 32% had a sensitivity of 65.5% and specificity of 62.8% for failure. Prolonged membrane rupture (PROM) and high GA were associated with extubation success in multivariate logistic regression analysis.
Conclusions:
High GA and PROM were associated with extubation success. Pre- and post-extubation FiO2 values were not significantly predictive of extubation failure. Further studies should evaluate if overall assessment, including ventilatory parameters and clinical factors, can predict extubation success in neonates.
More Related Videos
04:30Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...