Related Experiment Video
Updated: Oct 6, 2025

Author Spotlight: Standardizing the Development of Amine-Based Silica Composites as CO2 Adsorbents for Direct Air Capture
Published on: September 29, 2023
Analysis of Influencing Factors on the Gas Separation Performance of Carbon Molecular Sieve Membrane Using Machine
Yanqiu Pan1, Liu He1,2, Yisu Ren3
1School of Chemical Engineering, Dalian University of Technology, Dalian 116024, China.
Abstract:
Gas separation performance of the carbon molecular sieve (CMS) membrane is influenced by multiple factors including the microstructural characteristics of carbon and gas properties. In this work, the support vector regression (SVR) method as a machine learning technique was applied to the correlation between the gas separation performance, the multiple membrane structure, and gas characteristic factors of the self-manufactured CMS membrane. A simple quantitative index based on the Robeson's upper bound line, which indicated the gas permeability and selectivity simultaneously, was proposed to measure the gas separation performance of CMS membrane. Based on the calculation results, the inferred key factors affecting the gas permeability of CMS membrane were the fractional free volume (FFV) of the precursor, the average interlayer spacing of graphite-like carbon sheet, and the final carbonization temperature. Moreover, the most influential factors for the gas separation performance were supposed to be the two structural factors of precursor influencing the porosity of CMS membrane, the carbon residue and the FFV, and the ratio of the gas kinetic diameters. The results would be helpful to the structural optimization and the separation performance improvement of CMS membrane.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...