Related Experiment Video
Updated: Oct 6, 2025
![Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58491.jpg&w=3840&q=50)
Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Comparison of zero echo time MRI with T1-weighted fast spin echo for the recognition of sacroiliac joint structural
Yitong Li1, Yan Xiong1, Bowen Hou1
1Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China.
Objectives:
To evaluate the diagnostic performance of zero echo time (ZTE) MRI in the depiction of structural lesions of sacroiliac joints (SIJs) in patients with the suspicion of sacroiliitis compared with T1-weighted fast spin echo (T1 FSE), using CT as the reference standard.
Methods:
Forty patients with suspicion of sacroiliitis underwent both CT and MR scans of SIJs with 80 SIJs (160 bone articular surfaces) included for analysis. Two readers independently scored SIJs for structural lesions on CT and MR images. The diagnostic capability of ZTE MRI and T1 FSE were compared by the McNemar test, using CT as the reference standard. Agreements of diagnosis and sum scores of lesions between MR sequences and CT as well as between readers were also investigated using Cohen's κappa tests and intraclass correlation coefficients.
Results:
Diagnostic accuracy of ZTE MRI was higher than that of T1 FSE for erosions, sclerosis, and joint space changes (e.g., joint space changes: 91.3% vs 75.0%). ZTE MRI also improved sensitivity for detection of erosions and sclerosis (e.g., erosions at the joint level: 98.2% vs 80.0%) as well as specificity for detection of joint space changes (93.0% vs 67.4%). ZTE MRI had more consistency with CT than T1 FSE for both diagnosis and sum scores. Inter-reader agreements were higher for CT and ZTE MRI than those for T1 FSE.
Conclusions:
ZTE MRI showed superior diagnostic performance in the depiction of SIJ structural lesions compared with routine T1-weighted MRI and had reliability comparable to CT.
Key Points:
• ZTE MRI can provide CT-like bone contrast for the depiction of osseous structural lesions of the sacroiliac joints. • ZTE MRI showed superior diagnostic performance than conventional T1 FSE in the detection of osseous structural lesions of sacroiliitis, using CT as the reference standard. • In terms of inter-reader reliability, ZTE MRI performed comparably to CT and better than conventional T1 FSE.
More Related Videos
07:43In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Magnetic Resonance Imaging
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT