Airborne particle dispersion by high flow nasal oxygen: An experimental and CFD analysis
Caroline Crowley1, Brian Murphy2,3, Conan McCaul2,3,4
1School of Mechanical and Material Engineering, University College Dublin, Dublin, Ireland.
Abstract:
High Flow Nasal Oxygen (HFNO) therapy offers a proven means of delivering respiratory support to critically ill patients suffering from viral illness such as COVID-19. However, the therapy has the potential to modify aerosol generation and dispersion patterns during exhalation and thereby put healthcare workers at increased risk of disease transmission. Fundamentally, a gap exists in the literature with regards to the effect of the therapy on the fluid dynamics of the exhalation jet which is essential in understanding the dispersion of aerosols and hence quantifying the disease transmission risk posed by the therapy. In this paper, a multi-faceted approach was taken to studying the aerosol-laden exhalation jet. Schlieren imaging was used to visualise the flow field for a range of expiratory activities for three healthy human volunteers receiving HFNO therapy at flow rates of 0-60 L/min. A RANS turbulence model was implemented using the CFD software OpenFOAM and used to perform a parametric study on the influence of exhalation velocity and duration on the dispersion patterns of non-evaporating droplets in a room environment. A dramatic increase in the turbulence of the exhalation jet was observed when HFNO was applied. Quantitative analysis indicated that the mean exhalation velocity was increased by 2.2-3.9 and 2.3-3 times that for unassisted breathing and coughing, respectively. A 1-2 second increase was found in the exhalation duration. The CFD model showed that small droplets (10-40 μm) were most greatly affected, where a 1 m/s increase in velocity and 1 s increase in duration caused an 80% increase in axial travel distance.
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.