Related Experiment Video
Updated: Oct 5, 2025

In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
Thermal Cycling Effect on Locator System Retention and Metal Surface Roughness
Vladimir Perlis1, Tarek Mtanis1, Ameer Biadsee1
1Department of Oral Rehabilitation, School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel.
Purpose:
To estimate the effects of the thermal cycling (TC) process on the metal surfaces of Locators, as well as retention loss, and the correlation between them.
Materials And Methods:
Twenty-five new Locator R-Tx were included in the study. Four areas were marked on each Locators' patrix metal surface and scanned using a confocal scanner (μsurf explorer; NanoFocus). Three surface roughness parameters were measured in the scans: Sa (average distance of peaks from the central plain of the area), Vmp (volume of the peaks in the area), and Spc (mean curvature of the peaks describing the degree of their sharpness). Retention test was performed using Instron® 4500 compression tension tensile tester at a speed of 10 mm/min. The retention tests were done using a working model made of two acrylic blocks in which the Locator system parts were inserted. The surface parameters measurements and the retention tests were performed 2 times, once before and once after TC. The Locators were subjected to 15,000 TC cycles by investing them into 2 tubs with different water temperatures, 55°C and 5°C. During each 60-second cycle, the Locators were submerged in each tub for 20 seconds, with a 10 second transition time between the tubs. The post-TC retention and surface parameters measurements were compared with those prior to TC and the prior to TC measurements served as controls. Changes in parameters before and after TC were analyzed by a two-way ANOVA nested model with random intercept and slope by restricted maximum likelihood method. Correlation between retention and surface parameters was quantified and examined using Kendall's correlation test. The findings were considered statistically significant if p < 0.05.
Results:
There was a significant decrease in retention of 16.6N at the second retention test (p < 0.001). A significant statistical decrease in surface parameters were measured after TC process, Sa and Vmp (18 ×10-3 μm, p = 0.041 and 0.94 ×10-3 1/μm, p = 0.001, respectively). A significant statistical increase in Spc of 6.4 ×10-3 μm3 /μm2 (p = 0.023) was noticed. The correlation between retention decreases and surface changes was not statistically significant.
Conclusion:
The TC process causes a substantial reduction in retention to the Locator system over time. In addition, TC causes significant but minor changes to the Locator surface area. Most of the changes are in the horizontal dimension.
More Related Videos
11:11Experimental Methods for Investigation of Shape Memory Based Elastocaloric Cooling Processes and Model Validation
Published on: May 2, 2016
10:41The Effect of Charging and Discharging Lithium Iron Phosphate-graphite Cells at Different Temperatures on Degradation
Published on: July 18, 2018