Related Experiment Video
Updated: Oct 5, 2025

Experimental Column Setup for Studying Anaerobic Biogeochemical Interactions Between Iron OxyHydroxides, Trace Elements, and Bacteria
Published on: December 19, 2017
Biosorption of heavy metals: Transferability between batch and column studies
Chaamila Pathirana1, Abdul M Ziyath2, Prasanna Egodawatta3
1Department of Forestry and Environmental Science, University of Sri Jayewardenepura, Nugegoda, Sri Lanka; Posgraduate Institute of Agriculture, University of Peradeniya, Sri Lanka; Faculty of Engineering, Queensland University of Technology (QUT), GPO Box 2434, Brisbane, 4001, Queensland, Australia.
Abstract:
The design of an industrial water treatment system using sorption is based on laboratory column tests. To verify the applicability of a column sorption system at industrial scale, it is necessary to determine the system's breakthrough time (BT) in a laboratory setting. In a laboratory column set-up, BT is referred to as the time taken by the adsorbate to appear at column outlet for the first time. This is when the mass transfer zone (MTZ), where the equilibrium sorption occurs, reaches the end of the sorbent bed. However, such laboratory set-up requires significant resources including laboratory space, time and multiple trials, which is the opposite to the batch experimental approach that is commonly used to assess efficiency of sorbents. This study identified batch sorption parameters that can be used to determine BT for a column sorption setting for three toxic heavy metals commonly found in industrial wastewater, namely, Pb2+, Cd2+ and Cu2+. The study conducted a comprehensive evaluation of the relationships between column BT and its key influential factors, namely, equilibrium sorption capacity (qe), pseudo second-order kinetic rate constant (k2) and initial sorption rate (h). The results revealed that BT can be better estimated using h compared to qe and k2. As such, a batch experiment which is more resource efficient could be undertaken for an initial estimation of the experimental BT of a column system. Moreover, a simulation model developed to replicate column sorption could demonstrate the behaviour of the breakthrough curve, which is a key to the selection and assessment of the performance of a sorbent in an adsorbent column. The estimation errors in qe and k2 were found to influence the simulation outcomes. Hence, it is necessary to further investigate the other factors that can potentially influence sorption behaviour.
Related Concept Videos
Extraction: Advanced Methods
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Analyte Adsorption and Distribution
Principles Of Column Chromatography