Measuring Left Ventricular Pressure in Late Embryonic and Neonatal Mice
Published on: February 23, 2012
[Noninvasive estimation of left ventricular end-systolic pressure]
Abstract:
A method for noninvasively determining left ventricular (LV) end-systolic pressure (ESP) using carotid pulse tracings and cuff-measured blood pressure was re-evaluated. It was validated during diagnostic cardiac catheterization in 60 patients with cardiovascular diseases. LVESP calculated by this method and systolic blood pressure measured by the cuff were compared with aortic dicrotic notch pressures obtained by a catheter-tip manometer system as true LVESP. The calculated ESP was measured by the following formula; [the ratio of the excursion of dicrotic notch (b) to the peak (a) in carotid pulse tracings: (b/a) x pulse pressure] + diastolic blood pressure. This calculated ESP had a high correlation coefficient with true ESP invasively measured (r = 0.96), but was estimated to be 5.3 +/- 5.0 mmHg less than true ESP. Systolic blood pressure, used as a noninvasive index of ESP, accurately estimated ESP, but it was higher by 14.8 +/- 11.2 mmHg (r = 0.84). Calculated ESP measured by the present method was not affected by age or systemic vascular resistance. This is a reliable noninvasive means of estimating LV end-systolic pressure. Compared with the peak arterial pressure, this is a better parameter for the analysis of LV contractility, such as stress-shortening, and end-systolic pressure-volume relations.
More Related Videos
10:33Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
09:37Permanent Ligation of the Left Anterior Descending Coronary Artery in Mice: A Model of Post-myocardial Infarction Remodelling and Heart Failure
Published on: December 2, 2014
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure