Related Experiment Video
Updated: Oct 5, 2025

Closure of a Patent Foramen Ovale PFO: An Intervention Sequence
Published on: December 23, 2022
Lower transfer factor of the lung for carbon monoxide in women with a patent foramen ovale
Annalisa E Schallerer1, Joseph W Duke2, Julia P Speros1
1Department of Human Physiology, University of Oregon, Eugene, Oregon, USA.
New Findings:
What is the central question of this study? Do individuals with a patent foramen ovale (PFO+ ) have a lower lung transfer factor for carbon monoxide than those without (PFO- )? What is the main finding and its importance? We found a lower rate constant for carbon monoxide uptake in PFO+ compared with PFO- women, which was physiologically relevant (≥0.5 z-score difference), but not for PFO+ versus PFO- men. This suggests that factors independent of the PFO are responsible for our findings, possibly inherent structural differences in the lung.
Abstract:
The transfer factor of the lung for carbon monoxide (TLCO ) measure assumes that all cardiac output flows through the pulmonary circuit. However, right-to-left blood flow through a shunt can result in a lower transfer factor than predicted. A patent foramen ovale (PFO) is a potential source of right-to-left shunt that is present in ∼35% of the population, but the effect of PFO on TLCO is unknown. We sought to determine the effect of PFO on the TLCO . We conducted a retrospective analysis of TLCO data from 239 (101 women) participants. Anthropometrics and lung function, including spirometry, plethysmography and TLCO , were compiled from our previously published work. Women, but not men, with a PFO had a significantly lower TLCO and rate constant for carbon monoxide uptake (KCO ) (percentage of predicted and z-score) than women without a PFO. Women and men with a PFO had normal alveolar volumes that did not differ from those without a PFO. Correcting the data for haemoglobin in a subset of subjects did not change the results (n = 58; 25 women). The lower KCO in women with versus without a PFO was physiologically relevant (≥0.5 z-score difference). There was no effect of PFO in men. This suggests that factors independent of the PFO are responsible for our findings, possibly inherent structural differences in the lung.
More Related Videos
07:28Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Oxygen Transport in the Blood
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Gas Exchange and Transport