Reference-Free Adaptive Filtering of Extracellular Neural Signals Recording in Ultra-High Field Magnetic Resonance
Corey E Cruttenden1,2, Jennifer M Taylor2,3, Mahdi Ahmadi1
1University of Minnesota Department of Mechanical Engineering, 111 Church St. SE, Minneapolis, MN 55455.
Abstract:
This paper focuses on the removal of periodic artifacts from neural signals recorded in rats in ultra-high field (UHF) MRI scanners, using a reference free adaptive feedforward method. Recording extracellular neural signals in the UHF environment is motivated by the desire to combine neural recording and UHF functional magnetic resonance imaging (fMRI) to better understand brain function. However, the neural signals are found to have extremely high noise artifacts of a periodic nature due to electromagnetic interference and due to small oscillatory motions. In particular, noise at 60 Hz and several harmonics of 60 Hz, sinusoidal noise from a pump, and low frequency breathing motion artifacts are observed. Due to significant overlap between the noise frequencies and the neural frequency region of interest, band pass filters cannot be effectively utilized in this application. Hence, this paper develops adaptive least squares feedforward cancellation filters to remove the periodic artifacts. The interference fundamental frequency is identified precisely using an implementation of k-means in an iterative approach. The paper includes significant animal data from rats recorded in an IACUC-approved procedure in 9.4T and 16.4T MRI machines. For breathing artifacts filtered from 4 rats, the mean signal cancellation values at the harmonic interference frequencies are 5.18, 12.97, and 20.87 dB/Hz for a sliding template subtraction, a single-stage impulse reference method, and the cascaded adaptive filtering approach respectively. For pump artifacts filtered from 2 chronically implanted rats, mean signal cancellation values are 2.85, 9.52 and 12.06 dB/Hz respectively. The experimental results show that periodic noise is very effectively removed by the developed cascaded adaptive least squares feedforward algorithm.
More Related Videos
10:23Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
Published on: June 23, 2023
11:00Reliable Acquisition of Electroencephalography Data during Simultaneous Electroencephalography and Functional MRI
Published on: March 19, 2021