Related Experiment Video
Updated: Aug 12, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Computerized chromatographic peak detection using the trigg tracking signal. An application devised for use with an
T F Hartley1, J C Philcox, J F Beesley
1Division of Clinical Chemistry, Institute of Medical and Veterinary Science, Adelaide, Australia.
Abstract:
Manual integration of the amino acid peaks from physiological samples produced by conventional anion exchange liquid chromatography is a time-consuming process. This paper describes a combined unit, consisting of an analog to digital converter and a personal computer, which was connected in parallel with the chart recorder and the analyser's 570 nm channel of the colorimeter. The computer was programmed to log the digitized data, detect the start, maximum and end of each chromatographic peak, calculate the area under the peak and its retention time and provide a printout of the results at the end of the elution program. The computer program successfully exploited the Trigg Tracking Signal as both a peak detection and as a moving baseline monitoring device. This approach proved to have an equivalent performance to the manual method for 17 out of the 19 amino acids normally quantitated in physiological samples. The automated detection and quantitation of arginine was unsatisfactory due to its characteristically low profile peak shape, and proline was not measured because the device was not connected to the 440 nm channel of the colorimeter. The automated system provided economic and analytically acceptable solutions to the problem of providing an online integrator versatile enough to be used with the 255 min long amino acid analysis of physiological fluids.
More Related Videos
12:47Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors