Image quality of dual-energy cone-beam CT with total nuclear variation regularization
Lukas Schröder1, Uros Stankovic1, Simon Rit2
1Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
Abstract:
Despite the improvements in image quality of cone beam computed tomography (CBCT) scans, application remains limited to patient positioning. In this study, we propose to improve image quality by dual energy (DE) imaging and iterative reconstruction using least squares fitting with total variation (TV) regularization. The generalization of TV called total nuclear variation (TNV) was used to generate DE images. We acquired single energy (SE) and DE scans of an image quality phantom (IQP) and of an anthropomorphic human male phantom (HMP). The DE scans were dual arc acquisitions of 70 kV and 130 kV with a variable dose partitioning between low energy (LE) and high energy (HE) arcs. To investigate potential benefits from a larger spectral separation between LE and HE, DE scans with an additional 2 mm copper beam filtration in the HE arc were acquired for the IQP. The DE TNV scans were compared to SE scans reconstructed with FDK and iterative TV with varying parameters. The contrast-to-noise ratio (CNR), spatial frequency, and structural similarity (SSIM) were used as image quality metrics. Results showed largely improved image quality for DE TNV over FDK for both phantoms. DE TNV with the highest dose allocation in the LE arm yielded the highest CNR. Compared to SE TV, these DE TNV results had a slightly lower CNR with similar spatial resolution for the IQP. A decrease in the dose allocated to the LE arm improved the spatial resolution with a trade-off against CNR. For the HMP, DE TNV displayed a lower CNR and/or lower spatial resolution depending on the reconstruction parameters. Regarding the SSIM, DE TNV was superior to FDK and SE TV for both phantoms. The additional beam filtration for the IQP led to improved image quality in all metrics, surpassing the SE TV results in CNR and spatial resolution.
More Related Videos
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT