Related Experiment Video
Updated: Oct 5, 2025

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Use of the SpO2/FiO2 Diagram to Assess Gas Exchange in Horses Under General Anaesthesia
Annalaura Scardia1, Eutalio L Mariani Pimenta2, Robert I Ross Russell3
1Universidade Federal de Minas Gerais - Hospital Veterinário - Escola de Veterinária, Belo Horizonte, Brasil; Department of Emergencies and Organ Transplantation, Section of Veterinary Clinics and Animal Production, University of Bari, Bari, Italy.
Abstract:
The aim of this study was to evaluate the validity of the SpO2/FiO2 diagram in estimating gas exchange in horses under general anaesthesia. In this prospective, controlled clinical study were included 10 horses under general anaesthesia. FiO2 was progressively reduced with the following steps: 0.6, 0.4, 0.3 and 0.21; SpO2 was recorded at each step. An arterial blood sample was collected at the steps of 1.0 and 0.21, to calculate intrapulmonary shunt with the Fshunt formula. The Fshunt value calculated at 0.21 FiO2 was defined as "Fshunt 0.21", the one calculated at 1.0 FiO2 as "Fshunt 1.0". The FiO2 vs SpO2 data points were analyzed using a computer algorithm which uses the haemoglobin and a fixed value for arterial-venous oxygen difference of 3.5 mL/dL. The algorithm estimates a shunt value fitting the obtained data with an ideal SpO2/FiO2 curve. The value of shunt (Sshunt) was considered for the study. Correlation between "Fshunt 1.0", "Fshunt0.21" and SShunt was determined using the Spearman Rank Correlation Coefficient test, the analysis of the regression curve and the coefficient of determination (r2). Values of P < .05 were considered statistically significant. A significant and strong correlation (P = .0069; r = 0.839; r2=0.6194) and a significant and moderate correlation (P = .0443; r = 0.644; r2=0.2336) was found between Sshunt and "Fshunt 1.0" and between Sshunt and "Fshunt 0.21", respectively. The SpO2/FiO2 diagram proved to be a useful and non-invasive tool to characterize gas exchange in horses under general anaesthesia and mechanical ventilation.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Stages of General Anesthesia
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...

