Related Experiment Video
Updated: Oct 5, 2025

Detection of Viruses from Bioaerosols Using Anion Exchange Resin
Published on: August 22, 2018
Respiratory pandemic and indoor aeraulics of classrooms
P Carlotti1, B Massoulié2, A Morez2
1Artelia, 47 avenue de Lugo, 94600 Choisy le Roi, France.
Abstract:
Respiratory pandemics, such as COVID19, may be transmitted by several modes. The present work focuses on the transmission through small droplets released by people from their mouth by breathing, speaking, coughing, sneering, and possibly aspirated by other people around through their respiration. An analysis of droplet evolution in simplified situations shows that the droplets reach very quickly a quasi-equilibrium temperature before encompassing an isothermal evaporation process. The removal of droplets from suspension is thus piloted by balance between evaporation and sedimentation. It is shown that ambient relative humidity is a major factor influencing the lifetime of droplets and the distance they may travel. As a consequence, and independently of any other health consideration linked to ambient humidity, it is seen that a dry air is a favourable factor for limiting risk of contamination from COVID19. Further investigation is made using computational fluid dynamics (CFD) in a classroom geometry. Several ventilation strategies are investigated: classical regulatory mechanical ventilation, open window natural ventilation and displacement natural ventilation. Ventilation has several effects which influence contamination risk: by introducing fresh air, it reduces droplet concentration; humidity released by human occupants is also limited. However, these effects are not uniform in space, and depend on ventilation strategy. Application of a dose-effect model calibrated for COVID19 to CFD results allows to estimate contamination risk. It is shown that contamination risk is higher for regulatory mechanical ventilation, and may be reduced, using natural ventilation in the absence of wind, by a factor 2.3 to nearly 3 when the teacher is sick, and by a factor 6 to 500 when a student is sick. In the presence of wind, the reduction factor is as high as 13 when the teacher is sick and 17 when a student is sick.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Common Respiratory Disorders
Upper respiratory disorders impact the airways above the vocal cords, encompassing areas like the nose, sinuses, and throat. Various conditions fall under this category, including the common cold and allergic rhinitis. These disorders can stem from several causes,...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Other Pulmonary Disorders