Related Experiment Video
Updated: Oct 5, 2025

A Visual Guide to Sorting Electrophysiological Recordings Using 'SpikeSorter'
Published on: February 10, 2017
Objective evaluation of stimulation artefact removal techniques in the context of neural spike sorting
Maarten Schelles1, Jasper Wouters2, Boateng Asamoah3
1KU Leuven, Electrical Engineering Department (ESAT), MNS Micro- and Nanosystems, Leuven, Belgium.
Abstract:
Objective. We present a framework to objectively test and compare stimulation artefact removal techniques in the context of neural spike sorting.Approach. To this end, we used realistic hybrid ground-truth spiking data, with superimposed artefacts fromin vivorecordings. We used the framework to evaluate and compare several techniques: blanking, template subtraction by averaging, linear regression, and a multi-channel Wiener filter (MWF).Main results. Our study demonstrates that blanking and template subtraction result in a poorer spike sorting performance than linear regression and MWF, while the latter two perform similarly. Finally, to validate the conclusions found from the hybrid evaluation framework, we also performed a qualitative analysis onin vivorecordings without artificial manipulations.Significance. Our framework allows direct quantification of the impact of the residual artefact on the spike sorting accuracy, thereby allowing for a more objective and more relevant comparison compared to indirect signal quality metrics that are estimated from the signal statistics. Furthermore, the availability of a ground truth in the form of single-unit spiking activity also facilitates a better estimation of such signal quality metrics.