Related Experiment Video
Updated: Oct 5, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
A probabilistic approach for determining Monte Carlo beam source parameters: II. Impact of beam modeling
Jasmine Duchaine1,2, Mathilde Wahl1,2, Daniel Markel3
1Département de Physique, Université de Montréal, Campus MIL, 1375 Av. Thérèse Lavoie-Roux, Montréal, QC H2V 0B3, Canada.
Abstract:
Objective.The Monte Carlo method is recognized as a valid approach for the evaluation of dosimetric functions for clinical use. This procedure requires the accurate modeling of the considered linear accelerator. In Part I, we propose a new method to extract the probability density function of the beam model physical parameters. The aim of this work is to evaluate the impact of beam modeling uncertainties on Monte Carlo evaluated dosimetric functions and treatment plans in the context of small fields.Approach.Simulations of output factors, output correction factors, dose profiles, percent-depth doses and treatment plans are performed using the CyberKnife M6 model developed in Part I. The optimized pair of electron beam energy and spot size, and eight additional pairs of beam parameters representing a 95% confidence region are used to propagate the uncertainties associated to the source parameters to the dosimetric functions.Main results.For output factors, the impact of beam modeling uncertainties increases with the reduction of the field size and confidence interval half widths reach 1.8% for the 5 mm collimator. The impact on output correction factors cancels in part, leading to a maximum confidence interval half width of 0.44%. The impact is less significant for percent-depth doses in comparison to dose profiles. For these types of measurement, in absolute terms and in comparison to the reference dose, confidence interval half widths less than or equal to 1.4% are observed. For simulated treatment plans, the impact is more significant for the treatment delivered with a smaller field size with confidence interval half widths reaching 2.5% and 1.4% for the 5 and 20 mm collimators, respectively.Significance.Results confirm that AAPM TG-157's tolerances cannot apply to the field sizes studied. This study provides an insight on the reachable dose calculation accuracy in a clinical setup.
More Related Videos
Related Concept Videos
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Propagation of Uncertainty from Systematic Error
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Dose Size and Dosing Frequency: Determination Methods
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by