Related Experiment Video
Updated: Oct 5, 2025

Gasless Endoscopic Thyroidectomy via the Trans-Axillary Approach
Published on: September 15, 2023
Video-Assisted Thyroidectomy Using a Surgical Energy Device: Initial Experience in a Japanese Single-Center Cohort
Jun-Ichi Ohkubo1, Tetsuro Wakasugi1, Shoko Takeuchi1
1Department of Otorhinolaryngology-Head and Neck Surgery, School of Medicine, University of Occupational and Environmental Health, Kitakyushu, Japan.
Objective:
Video-assisted thyroidectomy (VAT) was approved for coverage under the Japanese public health insurance system in 2016. In our department, we introduced VAT in 2018, and we have since been performing the procedure with the assistance of surgical energy devices. We herein summarize our cases undergoing VAT, including a review of points to consider when introducing the procedure, and characteristics of the surgical energy devices.
Methods:
We enrolled 24 patients (14 women and 10 men; age: 24-83 years; mean: 59.0 years) with thyroid/parathyroid tumors who underwent VAT between January 2018 and March 2021 at our department. The medical records of the patients were reviewed, and demographic data, clinical characteristics, histological type, treatment outcomes, and complications were analyzed.
Results:
The surgical energy devices used were LigaSure® in the first 4 cases, Acrosurg®. Scissors S17 in the next 13 cases, and Acrosurg®. Revo S15 in the latest 7 cases. The operation time (range: 72-250 min; mean: 147 min), intraoperative blood loss (range: 5-370 mL; mean: 33 mL), indwelling time of wound drain (range: 2-6 days; mean: 3.5 days), and hospitalization period (range: 3-8 days; mean: 5.5 days) were within acceptable ranges. In this study, it is suggested that Acrosurg®. Revo S15 can shorten the indwelling time and the hospitalization period. There were no serious complications, but 1 patient developed transient vocal cord paralysis, which improved 3 months after surgery. It was suggested that the microwave energy devices, Acrosurg®. Scissors S17 and Acrosurg®. Revo S15, may be more effective with respect to sealing/hemostasis/coagulation capacity and controllability than the high-frequency electrosurgical device, LigaSure®.
Conclusion:
Based on this initial experience, VAT using surgical energy devices appeared to be a safe, effective, and minimally invasive procedure for the treatment of thyroid/parathyroid tumors. Further studies confirming these early findings are needed.
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Urologic Endoscopic Procedure: Cystoscopic Examination

