Related Experiment Video
Updated: Oct 5, 2025

Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
Human-Body-Temperature Triggerable Phase Transition of W-VO2@PEG Nanoprobes with Strong and Switchable NIR-II
Liantong Li1,2, Huazhen Chen1,2, Yujiao Shi1,2
1MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
Abstract:
The immense potential of temperature-responsive nanomaterials for use as contrast agents has propelled much recent research and development in the field of photoacoustic (PA) imaging, while the exorbitant transition temperature exceeding the human-tolerable range and the low reversibility of the reported temperature-sensitive nanosystems are still two severe issues that hinder effective imaging and long-term monitoring in practical applications. Herein, we propose a high-performing thermoresponsive polyethylene glycol-coated tungsten-doped vanadium dioxide (W-VO2@PEG) nanoprobe (NP) with strong and switchable optical absorption in the near-infrared-II (NIR-II) biowindow (1000-1700 nm) near human-body temperature, to achieve deep and contrast-enhanced PA imaging. Our study shows that the PA signal amplitude of W-VO2@PEG NPs at 1064 nm increases up to 260% when the temperature increases from 35 °C to 45 °C, with a signal fluctuation of less than 10% after 10 temperature cycles, therefore enabling great potential of "off-to-on" dynamic contrast-enhanced imaging capability in deep-seated tissues. Experiments on tissue-mimicking phantoms and in vitro chicken breast showed that, by levering the prepared W-VO2@PEG NPs and dynamically modulating the temperature field with an external NIR optical stimulus, contrast-enhanced PA images of the target can be obtained with an imaging depth up to 1.5 cm. Furthermore, in vivo potential of the prepared thermoresponsive NPs for the detection and identification of deep-seated tumors by directly comparing to conventional "always on" NPs has been demonstrated. Our work will offer feasible guidance for the development of smart temperature-activatable PA NPs with improved imaging depth and imaging contrast.
More Related Videos
09:01Magnetic-, Acoustic-, and Optical-Triple-Responsive Microbubbles for Magnetic Hyperthermia and Pothotothermal Combination Cancer Therapy
Published on: May 22, 2020
06:42Plasmonic Photothermal Cancer Therapy: Nanoparticle-embedded Tumor-tissue-mimicking Phantoms for Visualizing Photothermal Temperature Distribution
Published on: May 9, 2025
Related Concept Videos
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C...