Related Experiment Video
Updated: Oct 5, 2025

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
OPK_SNCA: Optimized prior knowledge via sparse non-convex approach for cone-beam X-ray luminescence computed
Haibo Zhang1, Linqi Hai1, Jiaojiao Kou1
1School of Information Sciences and Technology, Northwest University, Xi'an, Shannxi 710027, China.
Background:
The development of Cone-beam X-ray luminescence computed tomography (CB-XLCT) has allowed the quantitative in-depth biological imaging, but with a greatly ill-posed and ill-conditioned inverse problem. Although the predefined permissible source region (PSR) is a widely used way to alleviate the problem for CB-XLCT imaging, how to obtain the accurate PSR is still a challenge for the process of inverse reconstruction.
Methods:
We proposed an optimized prior knowledge via a sparse non-convex approach (OPK_SNCA) for CB-XLCT imaging. Firstly, non-convex Lp-norm optimization model was employed for copying with the inverse problem, and an iteratively reweighted split augmented lagrangian shrinkage algorithm was developed to obtain a group of sparse solutions based on different non-convex p values. Secondly, a series of permissible regions (PRs) with different discretized mesh was further achieved, and the intersection operation was implemented on the group of PRs to get a reasonable PSR. After that, the final PSR was adopted as an optimized prior knowledge to enhance the reconstruction quality of inverse reconstruction.
Results:
Both simulation experiments and in vivo experiment were performed to evaluate the efficiency and robustness of the proposed method.
Conclusions:
The experimental results demonstrated that our proposed method could significantly improve the imaging quality of the distribution of X-ray-excitable nanophosphors for CB-XLCT.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
X-ray Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT

