Titanium T-Plate as a Stabilizing Platform in the Management of Acquired Nystagmus and Oscillopsia Without a Null
Ying Chen1, Shanlee Stevens, Nicole Topilow
1Department of Ophthalmology, Dr. Nasser Ibrahim Al-Rashid Orbital Vision Research Center, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, Florida, U.S.A.
Abstract:
The primary goal of nystagmus treatment is to improve visual function and quality of life. Current surgical interventions are limited by regression of effect, serious complications, and reliance on a null zone. Tse and colleagues in 2017 reported the use of a T-plate/suture fixation platform for globe stabilization to treat acquired nystagmus and oscillopsia without a null zone in a patient with bilateral internuclear ophthalmoplegia. However, the improvement in nystagmus was not objectively quantified. This case series reports 2 patients who underwent bilateral T-plate placement which resulted in immediate and sustained improvement of nystagmus objectively measured by videonystagmography.