Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same journal

Compressed multi-scale entropy and its application in mechanical fault diagnosis.

The Review of scientific instruments·2026
Same journal

Bidirectional drive and multi-resolution adjustment across frequency bands in inertial impact piezoelectric motors via multimodal resonant vibration.

The Review of scientific instruments·2026
Same journal

A magnetic field sensor based on flaky Terfenol-D material and dual fiber grating.

The Review of scientific instruments·2026
Same journal

A novel E-field eight-way cavity combiner for high-power S-band applications.

The Review of scientific instruments·2026
Same journal

Constant radius blade spring suspended bench for vibration isolation.

The Review of scientific instruments·2026
Same journal

Qualification of infrared optical fibers and emitters for a spectrometer for in situ planetary exploration: Results from the TRIS (TRansmission and Illumination System) project.

The Review of scientific instruments·2026
See all related articles

Related Experiment Video

Updated: Oct 4, 2025

A Microfluidic-based Hydrodynamic Trap for Single Particles
10:13

A Microfluidic-based Hydrodynamic Trap for Single Particles

Published on: January 21, 2011

16.8K

A microfluidic valve with bubble trap and zero dead volume.

Tayebeh Saghaei1, Erik Reimhult1, Peter D J van Oostrum1

  • 1Department of Nanobiotechnology, Institute of Biologically Inspired Materials, University of Natural Resources and Life Sciences, Vienna, 1190 Vienna, Austria.

The Review of Scientific Instruments
|February 2, 2022
PubMed
Summary
This summary is machine-generated.

This study introduces a novel fluidic technique for rapid sample chamber content exchange with minimal liquid usage. The design minimizes sample waste and efficiently traps bubbles, offering an improved alternative to conventional methods.

More Related Videos

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

21.3K
Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology
07:03

Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology

Published on: December 1, 2023

1.1K

Related Experiment Videos

Last Updated: Oct 4, 2025

A Microfluidic-based Hydrodynamic Trap for Single Particles
10:13

A Microfluidic-based Hydrodynamic Trap for Single Particles

Published on: January 21, 2011

16.8K
Microfluidic Chips Controlled with Elastomeric Microvalve Arrays
18:11

Microfluidic Chips Controlled with Elastomeric Microvalve Arrays

Published on: October 1, 2007

21.3K
Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology
07:03

Author Spotlight: Integrating Computational and Experimental Approaches in Precision Oncology

Published on: December 1, 2023

1.1K

Area of Science:

  • Fluid Dynamics
  • Microfluidics
  • Analytical Chemistry

Background:

  • Minimizing sample consumption is crucial in microfluidic applications.
  • Conventional methods for sample exchange often involve significant liquid volumes and complex valve systems.
  • Efficient bubble trapping is essential for reliable fluidic operations.

Purpose of the Study:

  • To develop a technique for rapid sample chamber content exchange.
  • To minimize liquid consumption during sample changes.
  • To create a fluidic circuit with integrated bubble trapping capabilities.

Main Methods:

  • A novel fluidic circuit design was developed.
  • The design eliminates dead volume.
  • The circuit functions as a manifold for sequential liquid introduction.

Main Results:

  • The technique allows swift chamber content exchange using minimal fluid volumes (few times the chamber volume).
  • The design effectively minimizes mixing between consecutive liquids.
  • The fluidic circuit demonstrated efficient bubble trapping capabilities.

Conclusions:

  • The presented technique offers a significant improvement over standard solutions for sample chamber fluid exchange.
  • The design's efficiency in minimizing sample consumption and trapping bubbles makes it ideal for various microfluidic applications.
  • This approach provides a simpler and more effective alternative to complex valve-based systems.