Rapid evaporative ionization mass spectrometry (intelligent knife) for point-of-care testing in acute aortic
Hannah A Davies1,2, Eva Caamano-Gutierrez3,4, Joscelyn Sarsby4,5
1Department of Cardiovascular and Metabolic Medicine, Institute of Life Course and Medical Sciences, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, UK.
Objectives:
Rapid evaporative ionization mass spectrometry (REIMS) can discriminate aneurysmal from normal aortic tissue. Our objective in this work was to probe the integrity of acute dissection tissue using biomechanical, biochemical and histological techniques and demonstrate that REIMS can be used to discriminate identified differences.
Methods:
Human aortic tissue was obtained from patients undergoing surgery for acute aortic dissection. Biomechanical, biochemical and histological assessment was carried out to probe mechanical properties and elastin, collagen and glycosaminoglycan composition of the tissue. Monopolar electrocautery was applied to samples and surgical aerosol aspirated and analysed by REIMS to produce mass spectral data.
Results:
Tissue was obtained from 10 patients giving rise to 26 tissue pieces: 10 false lumen (FL), 10 dissection flap and 6 true lumen samples. Models generated from biomechanical and biochemical data showed that FL tissue was distinct from true lumen and dissection flap tissue. REIMS identified the same pattern being able to classify tissue types with 72.4% accuracy and 69.3% precision. Further analysis of REIMS data for FL tissue suggested patients formed 3 distinct clusters. Histological and biochemical assessment revealed patterns of extracellular matrix degradation within the clusters that are associated with altered tissue integrity identified using biomechanical testing.
Conclusions:
Structural integrity of the FL in acute Type A dissection could dictate future clinical distal disease progression. REIMS can detect differences in tissue integrity, supporting its development as a point-of-care test to guide surgical intraoperative decision-making.
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Emission Spectroscopy: Lab
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...