Are There Bad ICU Rooms? Temporal Relationship between Patient and ICU Room Microbiome, and Influence on
Daniel E Freedberg1, Miles Richardson2,3, Mary Nattakom4
1Division of Digestive and Liver Diseases, Columbia University, New York, New York, USA.
Abstract:
The gut microbiome of an individual can shape the local environmental surface microbiome. We sought to determine how the intensive care unit (ICU) patient gut microbiome shapes the ICU room surface microbiome, focusing on vancomycin-resistant Enterococcus (VRE), a common ICU pathogen. This was an ICU-based prospective cohort study. Rectal swabs were performed in adult ICU patients immediately at the time of ICU admission and environmental surface swabs were performed at five predetermined time points. All swabs underwent 16S rRNA gene sequencing and culture for VRE. 304 ICU patients and 24 ICU rooms were sampled (5 longitudinal samples per ICU room). Spatially adjacent ICU rooms were no more microbially similar than nonadjacent rooms. Microbial signatures within rooms diverged rapidly over time: in 14 days, ICU rooms were as similar to other ICU rooms as they were to their prior selves. This divergence over time was more pronounced in rooms with higher patient turnover. Examining VRE status by culture, patient VRE gut colonization had modest agreement with room surface VRE (kappa statistic 0.36). There were no ICU rooms that consistently cultured positive for VRE, including those that housed VRE positive patients. Individual ICU patients had a limited impact on ICU room surface microbiome, and rooms diverged similarly over time regardless of patients. Patient VRE gut colonization may have a modest influence on room surface VRE but there were no "bad rooms" that consistently cultured positive for VRE. These results may be useful in planning infection control measures. IMPORTANCE This study found that intensive care unit (ICU) room microbial signatures diverged from their baseline quickly: within 2 weeks, individual ICU rooms had lost distinguishing characteristics and were as similar to other ICU rooms as they were to their former selves. Patient turnover within rooms accelerated this drift. Patient gut colonization with vancomycin-resistant Enterococcus (VRE) was associated with ICU room surface contamination with VRE; again, within 2 weeks, this association was substantially diminished. These results provide dynamic information regarding how patients control the microbiota on local hospital room surfaces and may facilitate decision making for infection prevention and control measures targeting VRE or other organisms.
More Related Videos
03:53Growing a Cystic Fibrosis-Relevant Polymicrobial Biofilm to Probe Community Phenotypes
Published on: April 19, 2024
06:43Studying Microbial Communities In Vivo: A Model of Host-mediated Interaction Between Candida Albicans and Pseudomonas Aeruginosa in the Airways
Published on: January 13, 2016
Related Concept Videos
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Antimicrobial Effectiveness
