Related Experiment Video
Updated: Oct 4, 2025

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Analysis of measurement changes in pelvic incidence according to pelvic rotation using a three-dimensional model
Ki Young Lee1, Jung-Hee Lee2, Sang-Kyu Im1
1Department of Orthopaedic Surgery, Graduate School, College of Medicine, Kyung Hee University, 23, Kyungheedae-ro, Dongdaemun-gu, Seoul, 130-872, South Korea.
Background:
Pelvic incidence (PI) is used as a key parameter in surgical correction of adult spinal deformity (ASD). However, reflecting the exact center or inclination of the three-dimensional anatomical structures on the two-dimensional (2D) sagittal radiographs is limited, resulting in measurement errors. Therefore, we evaluated whether there is a change in PI measurement according to the actual rotation of the pelvis, and conducted a study on a more accurate method for PI measurement using 2D sagittal radiographs.
Methods:
From 2014 to 2015, the data of 30 patients who visited our outpatient clinic were analyzed retrospectively. CT scans including those of the lower lumbar spine, pelvis, and both femurs in the DICOM format were imported to Mimics Research 17.0 (Materialise NV, Belgium), SolidWorks (Dassault systems, France), and AutoCAD 2014 (AUTODESK, US). The changes in PI according to vertical and horizontal pelvic rotations were evaluated.
Results:
The average PIs according to the horizontal pelvic rotations measured on AutoCAD with 0°, 5°, 10°, 15°, 20°, 25°, 30°, 35°, and 40° were 48.8°, 48.7°, 48.3°, 47.8°, 46.9°, 45.6°, 44.0°, 42.2°, and 39.9°, respectively. The PI with an acceptable error of 6° on radiographs was 35° in the horizontal pelvic rotation. The average PIs according to the vertical pelvic rotations measured on AutoCAD with 0°, 5°, 10°, 15°, 20°, 25°, 30°, 35°, and 40° were 48.8°, 49.0°, 49.5°, 50.2°, 51.3°, 52.7°, 54.4°, 56.6°, and 59.4°, respectively. The PI with an acceptable error of 6° on radiographs was 30° in the vertical pelvic rotation.
Conclusions:
This study revealed that the PI value could differ from the actual anatomical value due to the horizontal and vertical rotation of the pelvis while acquiring the radiograph. Regarding whole-spine lateral radiographs, errors in PI measurement may occur due to pelvic rotation or nonvertical projection of X-rays. In the standing pelvic lateral radiographs, ensuring superposition of the femoral heads at the center and obtaining the straight sacral endplate by referring to CT or magnetic resonance imaging would be a more accurate measurement method to define PI.
Related Concept Videos
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...
Transformation of Plane Stress
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...

