Related Experiment Video
Updated: Oct 4, 2025

06:55
Kinematic History of a Salient-recess Junction Explored through a Combined Approach of Field Data and Analog Sandbox Modeling
Published on: August 5, 2016
8.3K
Gas fields and large shallow seismogenic reverse faults are anticorrelated
G Valensise1, F Donda2, A Tamaro2
1Istituto Nazionale di Geofisica e Vulcanologia-INGV, Rome, Italy. gianluca.valensise@ingv.it.
Scientific Reports
|February 4, 2022
Summary
Productive gas wells are less common near seismogenic faults. Earthquake ruptures may lead to gas loss, suggesting intact reservoirs are often found near aseismic faults.
Area of Science:
- Geosciences
- Petroleum Geology
- Seismology
Background:
- Understanding the relationship between geological structures and hydrocarbon reservoirs is crucial for energy exploration.
- Seismogenic faults pose risks to subsurface integrity and resource containment.
Purpose of the Study:
- To investigate the spatial correlation between seismogenic faults and gas wells in Italy.
- To assess the impact of fault activity on hydrocarbon reservoir viability.
Main Methods:
- Geographic Information System (GIS) analysis.
- Statistical correlation techniques applied to fault and well data.
- Spatial analysis of 18 seismogenic faults and 1651 gas wells.
Main Results:
- A significant negative correlation was observed between productive gas wells and seismogenic faults.
- Unproductive wells were frequently located near or above seismogenic faults.
- Earthquake ruptures may cause significant gas loss over geological timescales.
Conclusions:
- Reservoirs located above smaller or aseismic faults are more likely to remain intact.
- Findings have implications for hydrocarbon exploration, fault behavior assessment, and underground energy storage in active tectonic regions.
- This research informs the public acceptance of carbon capture and storage (CCS) and other subsurface energy facilities.
Related Concept Videos
Fault Types
141
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
141
Local Attraction
141
Local attraction refers to disturbances in compass readings caused by magnetic influences from nearby objects such as metal fences, buried pipes, vehicles, buildings, power lines, or natural iron ore deposits. Small items like wristwatches, steel tools, or belt buckles can also interfere with the compass by creating local magnetic fields that distort the Earth's natural magnetic field. These distortions lead to inaccurate readings, posing navigation and land surveying challenges.Local...
141
Power System Three-Phase Short Circuits
166
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
166
Magnetic Susceptibility and Permeability
1.5K
In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
1.5K
Directional Relays
231
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
231
Induced Electric Fields
4.0K
The fact that emfs are induced in circuits implies that work is being done on the conduction electrons in the wires. What can possibly be the source of this work? We know that it’s neither a battery nor a magnetic field, as a battery does not have to be present in a circuit where current is induced, and magnetic fields never do any work on moving charges. The source of the work is in fact an electric field that is induced in the wires. For example, if a stationary conductor is placed in a...
4.0K