For the past 20 years, many hypertension guidelines have strongly recommended the practical use of ambulatory blood pressure monitoring (ABPM) to the diagnosis and management of hypertension. However, whether different sleep conditions during ABPM will affect blood pressure (BP) fluctuations and lead to inaccurate measurement results is a concern of clinicians.
Method:
This was a prospective cohort study in the real-world setting. The participants were recruited between June 2018 and June 2019 in Hebei Province, China. There are three types of sleep during ABPM: undisturbed sleep, disturbed sleep and severely disturbed sleep. The people were divided into three groups according to their sleep types during ABPM. The primary outcome is 24-h mean BP, circadian rhythm of BP and variation coefficient of 24-h BP. Comparisons between groups are tested by Kruskal-Wallis H test.
Results:
In total 1154 people completed the study. There was no significant difference in 24-h mean BP and circadian rhythm of BP among the three groups. There are statistically significant differences among the three groups in the variation coefficient of 24-h BP for the general population and noninsomnia population. There was no significant difference in mean BP, circadian rhythm of BP and variation coefficient of BP among the three groups for the insomnia people.
Conclusion:
Regardless of the insomniac or noninsomniac population, sleep conditions during ABPM do not affect BP value and BP rhythm. For noninsomniac people, the sleep situation during ABPM may affect the BP variation coefficient.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...