Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
Changes in corneal densitometry after long-term orthokeratology for myopia and short-term discontinuation
Lianghui Zhao1,2,3, Lili Jing1,2, Jie Li1,2
1Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China.
Purpose:
To quantify changes in corneal densitometry after long-term orthokeratology treatment in myopic children and to analyze the reversibility one month after discontinuation.
Methods:
Seventy-four myopic subjects aged 8-16 years, who wore orthokeratology lenses for two years, were divided into relatively steep- (lens movement within 1.0-1.5 mm, thirty-six participants) and flat-fitting groups (lens movement within 1.5-2.0 mm, thirty-eight participants). Based on refractive errors, they were divided into low and moderate myopia groups (thirty-seven participants in each group). Corneal densitometry was performed using Pentacam (Oculus Optikgeräte GmbH, Wetzlar, Germany) at each follow-up timepoint. Repeated-measures analysis of variance was used to compare the parameters before and after orthokeratology.
Results:
The corneal densitometry values over the 0-10 mm diameter area increased from 12.84±1.38 grayscale units (GSU) at baseline to 13.59±1.42 GSU after three-month orthokeratology (P = .001) and reached 14.92±1.45 GSU at two years (P < .001). An increase in densitometry began at one month (P = .001) over the 0-2 mm annulus compared with that at three months over the 2-6 mm and 6-10 mm zones (P = .002,.014). The densitometry values significantly increased at three months in the relatively steep-fitting group (P = .003) and at one year in the relatively flat-fitting group (P = .001). After discontinuation of orthokeratology for one month, the values showed no significant decrease.
Conclusions:
Long-term orthokeratology treatment causes a small but statistically significant increase in corneal densitometry values. During the first year, the onset of these changes was related to the fitting mode. Corneal densitometry values showed no significant reduction after one-month discontinuation.