Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Hepatic dual-contrast CT imaging: slow triple kVp switching CT with CNN-based sinogram completion and material
Wenchao Cao1, Nadav Shapira1, Andrew Maidment1
1University of Pennsylvania, Perelman School of Medicine, Department of Radiology, Philadelphia, Pennsylvania, United States.
Abstract:
Purpose: Dual-contrast protocols are a promising clinical multienergy computed tomography (CT) application for focal liver lesion detection and characterization. One avenue to enable multienergy CT is the introduction of photon-counting detectors (PCD). Although clinical translation is highly desired because of the diagnostic benefits of PCDs, it will still be a decade or more before they are broadly available. In our work, we investigated an alternative solution that can be implemented on widely used conventional CT systems (single source and integrating detector) to perform multimaterial spectral decomposition for dual-contrast imaging. Approach: We propose to slowly alternate the x-ray tube voltage between 3 kVp levels so each kVp level covers a few degrees of gantry rotation. This leads to the challenge of sparsely sampled projection data in each energy level. Performing the material decomposition (MD) in the sinogram domain is not directly possible as the projection images of the three energy levels are not angularly aligned. In order to overcome this challenge, we developed a convolutional neural network (CNN) framework for sparse sinogram completion (SC) and MD. To evaluate the feasibility of the slow kVp switching scheme, simulation studies of an abdominal phantom, which included liver lesions, were conducted. Results: The line-integral SC network yielded sinograms with a pixel-wise of the line-integrals compared to the ground truth. This provided acceptable image quality up to a switching angle of 9 deg per kVp. The MD network we developed allowed us to differentiate iodine and gadolinium in the sinogram domain. The average relative quantification errors for iodine and gadolinium were below 10%. Conclusions: We developed a slow triple kVp switching data acquisition scheme and a CNN-based data processing pipeline. Results from a digital phantom validation illustrate the potential for future applications of dual-contrast agent protocols on practically available single-energy CT systems.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET