Related Experiment Video
Updated: Oct 4, 2025

Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Atrial fibrillation detection using ambulatory smartwatch photoplethysmography and validation with simultaneous
Po-Cheng Chang1, Ming-Shien Wen1, Chung-Chuan Chou1
1Division of Cardiology, Department of Internal Medicine, Chang Gung Memorial Hospital, Linkou and Chang Gung University, Medical School, Taoyuan, Taiwan.
Background:
Atrial fibrillation (AF)-associated embolic stroke is preventable, and AF detection may help to prevent stroke in subjects with paroxysmal AF. We aimed to evaluate the AF detection performance of smartwatch photoplethysmography (PPG) and the feasibility of ambulatory monitoring for AF detection in the daily life.
Design And Methods:
Consecutive subjects who underwent ambulatory Holter electrocardiogram (ECG) monitoring for AF detection or AF burden evaluation were enrolled. The participants underwent 24 hours of simultaneous Holter ECG monitoring and continuous PPG recording using a Garmin smartwatch. The PPG signals were processed for noise rejection, beat detection, beat labeling, and rhythm labeling for each 5-minute segment. The accuracy of the PPG AF detection was calculated using the corresponding simultaneous Holter ECG as the AF diagnostic standard.
Results:
Among the 200 available participants, 112 participants (56%) developed AF (the AF group). The sensitivity, specificity, and positive predicted value of AF detection in participants were 97.3%, 88.6%, and 91.6%, respectively. The area under the receiver operating characteristic curve was 0.90. When the performance was analyzed in these 5-minute segments, the sensitivity, specificity, and positive predicted values of AF detection were 97.1%, 86.8%, and 89.7%, respectively.
Conclusions:
This study demonstrated the feasibility of ambulatory monitoring for AF detection using a commercial smartwatch in daily life. A smartwatch may be an alternative screening tool to standard ambulatory Holter monitoring.
More Related Videos
09:17High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias V: Evaluating Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation