Related Experiment Video
Updated: Oct 4, 2025

Step-by-Step Stapedotomy through Transcanal Exclusive Endoscopic Approach
Published on: March 5, 2022
Stapedotomy using skeeter drill and self-retaining ear canal retractor: a single surgeon's 1000-plus surgical
N Vishnu Swaroop Reddy1, M Sharma2, S Shekhar3
1Department of Otolaryngology, Head and Neck and Facial Plastic Surgery, Care hospitals, Hyderabad, India.
Objective:
This study aimed to evaluate the long-term hearing outcomes in stapedotomy surgery using skeeter oto-drill and to assess safety in difficult situations.
Method:
A retrospective study was conducted with 944 patients who underwent 1007 stapedotomy procedures over 16 years, performed by a single surgeon using a trans-canal approach and a self-retaining ear canal retractor. Hearing thresholds were calculated over four frequencies. Air-bone conduction hearing thresholds were obtained at 1, 5 and 10 years post-operatively and compared to the pre-operative records.
Results:
Out of 1007 operated ears with one year follow up, 98.61 per cent of cases showed a negligible air-bone gap of equal to or less than 5 dB, 1.19 per cent of cases showed an air-bone gap equal to or more than 5 dB but less than 10 dB, and only 0.2 per cent of cases showed an air-bone gap of more than 10 dB.
Conclusion:
In this study, using skeeter drill with a 0.6 mm diamond burr to make the fenestra was constant in all the cases and one of the safest techniques, showing persistent long-term hearing results.