Related Experiment Video
Updated: Oct 4, 2025

Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Development of a computational phantom for validation of automated noise measurement in CT images
Choirul Anam1, Heri Sutanto1, Kusworo Adi1
1Department of Physics, Faculty of Sciences and Mathematics, Diponegoro University, Jl. Prof. Soedarto SH, Tembalang, Semarang 50275, Central Java, Indonesia.
Abstract:
The purpose of this study was to develop a computational phantom for validation of automatic noise calculations applied to all parts of the body, to investigate kernel size in determining noise, and to validate the accuracy of automatic noise calculation for several noise levels. The phantom consisted of objects with a very wide range of HU values, from -1000 to +950. The incremental value for each object was 10 HU. Each object had a size of 15 × 15 pixels separated by a distance of 5 pixels. There was no dominant homogeneous part in the phantom. The image of the phantom was then degraded to mimic the real image quality of CT by convolving it with a point spread function (PSF) and by addition of Gaussian noise. The magnitude of the Gaussian noises was varied (5, 10, 25, 50, 75 and 100 HUs), and they were considered as the ground truth noise (NG). We also used a computational phantom with added actual noise from a CT scanner. The phantom was used to validate the automated noise measurement based on the average of the ten smallest standard deviations (SD) from the standard deviation map (SDM). Kernel sizes from 3 × 3 up to 27 × 27 pixels were examined in this study. A computational phantom for automated noise calculations validation has been successfully developed. It was found that the measured noise (NM) was influenced by the kernel size. For kernels of 15 × 15 pixels or smaller, the NMvalue was much smaller than the NG. For kernel sizes from 17 × 17 to 21 × 21 pixels, the NMvalue was about 90% of NG. And for kernel sizes of 23 × 23 pixels and above, NMis greater than NG. It was also found that even with small kernel sizes the relationship between NMand NGis linear with R2more than 0.995. Thus accurate noise levels can be automatically obtained even with small kernel sizes without any concern regarding the inhomogeneity of the object.
More Related Videos
09:57Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography