A different cardiac resynchronization therapy technique might be needed in some patients with nonspecific
Gábor Katona1, Zsuzsanna Szelényi2, Gábor Szénási3
1Department of Medicine and Hematology, Semmelweis University, Budapest, Hungary.
Background:
Current cardiac resynchronization therapy (CRT), devised to eliminate dyssynchrony in left bundle branch block (LBBB), works by pacing the latest activated left ventricular site (LALVS). We hypothesized that patients with nonspecific intraventricular conduction disturbance (NICD) pattern respond less favorably to CRT, because their LALVS is far away from that in LBBB.
Methods:
By measuring the amplitude and polarity of secondary ST-segment alterations in two optional frontal and horizontal surface electrocardiogram (ECG) leads and using a software, we determined the resultant 3D spatial secondary ST vector, which is directed 180o away from the LALVS, in 110 patients with LBBB pattern and 77 patients with NICD pattern and heart failure. To validate the ECG method, we also estimated the LALVS by echocardiography using 3D parametric imaging and 2D speckle tracking in 22 LBBB patients and 20 NICD patients. Patients with NICD pattern were subdivided according to their non-overlapping frontal plane resultant secondary ST vector ranges to the NICD-1 subgroup (n = 44) and the NICD-2 subgroup (n = 33).
Results:
Based on the software determined coordinates of the resultant 3D spatial secondary ST vector directed 180o away from the LALVS, the LALVSs were located leftward, posterosuperior in the LBBB group, slightly left, superior in the NICD-1 subgroup, and slightly left, posteroinferior in the NICD-2 subgroup. The LALVS determined by ECG and echocardiography matched in all patients, except two.
Conclusions:
In the NICD-2 subgroup, a remote LALVS was found from that in LBBB pattern, which might explain the high non-response rate of the NICD pattern to the current CRT technique.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Dysrhythmias VI: Management of Dysrhythmias
Electrophysiology of Normal Cardiac Rhythm
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Dysrhythmias IV: Characteristics of Bradyarrhythmias