Related Experiment Video
Updated: Oct 4, 2025

TBase - an Integrated Electronic Health Record and Research Database for Kidney Transplant Recipients
Published on: April 13, 2021
Transformation of Sequential Hospital and Outpatient Laboratory Data into Between-Day Reference Change Values
George S Cembrowski1, Andrew W Lyon2, Christopher McCudden3
1Faculty of Medicine & Dentistry, Laboratory Medicine and Pathology, University of Alberta, Alberta, Canada.
Background:
Serial differences between intrapatient consecutive measurements can be transformed into Taylor series of variation vs time with the intersection at time = 0 (y0) equal to the total variation (analytical + biological + preanalytical). With small preanalytical variation, y0, expressed as a percentage of the mean, is equal to the variable component of the reference change value (RCV) calculation: (CVA2 + CVI2)1/2.
Methods:
We determined the between-day RCV of patient data for 17 analytes and compared them to healthy participants' RCVs. We analyzed 653 consecutive days of Dartmouth-Hitchcock Roche Modular general chemistry data (4.2 million results: 60% inpatient, 40% outpatient). The serial patient values of 17 analytes were transformed into 95% 2-sided RCV (RCVAlternate), and 3 sets of RCVhealthy were calculated from 3 Roche Modular analyzers' quality control summaries and CVI derived from biological variation (BV) studies using healthy participants.
Results:
The RCVAlternate values are similar to RCVhealthy derived from known components of variation. For sodium, chloride, bicarbonate calcium, magnesium, phosphate, alanine aminotransferase, albumin, and total protein, the RCVs are equivalent. As expected, increased variation was found for glucose, aspartate aminotransferase, creatinine, and potassium. Direct bilirubin and urea demonstrated lower variation.
Conclusions:
Our RCVAlternate values integrate known and unknown components of analytic, biologic, and preanalytic variation, and depict the variations observed by clinical teams that make medical decisions based on the test values. The RCVAlternate values are similar to the RCVhealthy values derived from known components of variation and suggest further studies to better understand the results being generated on actual patients tested in typical laboratory environments.
Related Concept Videos
Interpreting Run Charts
Purpose of Health Records II
Flow Sheet
Here's a closer look at the examples of flowsheets commonly used by nurses:
Graphic Sheet Documentation:
Methods of Documentation VI: Case Management Model
For example, a patient with a chronic...
The X̄ Chart
The x̄ chart, often known as the individual control chart, is a crucial tool in statistical process control. It is designed to monitor process behavior and performance over time and is widely used in various industries to ensure that processes are operating at their optimum capacity and within specified limits.
A x̄ chart is constructed by plotting individual measurements of a quality...
Regression Toward the Mean