Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

A BASIC program for computer-assisted point-counting techniques.

R G Knol, P C de Wilde, P J Slootweg

    Analytical and Quantitative Cytology and Histology
    |March 1, 1986
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Do dental implants facilitate bone invasion in patients with oral squamous cell carcinoma? A case series.

    International journal of oral and maxillofacial surgery·2022
    Same author

    Clinicopathological characteristics and outcome of 31 patients with ETV6-NTRK3 fusion gene confirmed (mammary analogue) secretory carcinoma of salivary glands.

    Oral oncology·2018
    Same author

    Role of ancillary techniques in profiling unclassified laryngeal malignancies.

    Virchows Archiv : an international journal of pathology·2018
    Same author

    World Health Organization 4th edition of head and neck tumor classification: insight into the consequential modifications.

    Virchows Archiv : an international journal of pathology·2018
    Same author

    Periosteal fasciitis in a 7-year old girl: a diagnostic dilemma.

    International journal of oral and maxillofacial surgery·2017
    Same author

    Using a semi-conductor sequencing-based panel for genotyping of HPV-positive and HPV-negative oropharyngeal cancer: a retrospective pilot study.

    Clinical otolaryngology : official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-Laryngology & Cervico-Facial Surgery·2016
    Same journal

    Micronuclei and other nuclear anomalies in buccal mucosa following exposure to X-ray radiation.

    Analytical and quantitative cytology and histology·2012
    Same journal

    Color deconvolution. Optimizing handling of 3D unitary optical density vectors with polar coordinates.

    Analytical and quantitative cytology and histology·2012
    Same journal

    Nuclear morphometry in the differential diagnosis of eosinophilic renal epithelial tumors.

    Analytical and quantitative cytology and histology·2012
    Same journal

    Spectrum of prostatic nonepithelial tumors and tumorlike conditions with spindle cell features.

    Analytical and quantitative cytology and histology·2012
    Same journal

    A framework for quantitative assessment of Ki67 distribution in preneoplastic bronchial epithelial lesions.

    Analytical and quantitative cytology and histology·2012
    Same journal

    Classification and grading of noninvasive and invasive neoplasms of the urothelium.

    Analytical and quantitative cytology and histology·2012
    See all related articles

    This study introduces a BASIC program to speed up stereologic parameter estimation using point-counting on microcomputers. The software automates calculations for stereologic parameters (VV, AA, SV, BA, JV, KV, NV) and their statistical assessments.

    Area of Science:

    • Stereology
    • Quantitative Histology
    • Bioimage Analysis

    Background:

    • Point-counting is a fundamental stereologic technique for estimating parameters.
    • Manual point-counting is laborious and time-consuming.
    • Microcomputers offer potential for automating stereologic analyses.

    Purpose of the Study:

    • To develop a BASIC program to accelerate stereologic parameter estimation.
    • To reduce manual labor in stereologic analysis.
    • To provide statistical assessments for stereologic parameters.

    Main Methods:

    • A BASIC program was developed for Commodore CBM 64, SX 64, and Apple II[e] microcomputers.
    • The program utilizes a point-counting technique with user-defined keyboard shortcuts for event registration.

    Related Experiment Videos

  • It calculates stereologic parameters (VV, AA, SV, BA, JV, KV, NV) and statistical measures.
  • Main Results:

    • The program substantially facilitates and accelerates the point-counting technique.
    • It automates the calculation of stereologic parameters and their standard deviations/errors.
    • The software allows for investigator-defined parameters and standard stereologic parameters.

    Conclusions:

    • The developed program effectively automates stereologic parameter estimation.
    • It is accessible to nonprogrammers with basic stereology knowledge.