AuraGain™ versus i-gel™ for bronchoscopic intubation under continuous oxygenation: A randomised controlled trial
Christine N Svendsen1, Charlotte V Rosenstock1,2, Gine L Glargaard1
1Department of Anaesthesiology and Intensive Care, Nordsjaellands Hospital, Hillerød, Denmark.
This study found no significant difference in the total time for airway management when comparing the AuraGain™ and i-gel™ supraglottic airway devices for bronchoscopic intubation. Both devices effectively facilitated oxygenation and airway management in patients.
Area of Science:
- Anesthesiology
- Critical Care Medicine
- Respiratory Medicine
Background:
- Second-generation supraglottic airway (SGA) devices are recommended for oxygenation when mask ventilation and tracheal intubation fail.
- Tracheal intubation can be achieved through an SGA using a bronchoscope, providing a secure airway.
- Comparing different SGA devices is crucial for optimizing airway management strategies.
Purpose of the Study:
- To compare the AuraGain™ and i-gel™ supraglottic airway devices as conduits for flexible bronchoscopic intubation.
- To evaluate the total time for airway management and success rates of intubation through these devices.
- To assess the performance of these devices in a general patient population with variable anesthesiologist experience.
Main Methods:
- A randomized trial involving 100 patients allocated to either the AuraGain™ or i-gel™ group.
- 25 anesthesiologists each performed two intubations with each device in a random order.
- The primary outcome was the total time for airway management, from device insertion to successful intubation confirmed by capnography.
Main Results:
- Overall, 87% of patients were successfully intubated through the allocated SGA.
- No significant difference was found in the total time for airway management between the AuraGain™ (227s) and i-gel™ (199s) groups (p=0.076).
- The i-gel™ showed a significantly shorter placement time (37s) compared to the AuraGain™ (54s) (p<0.001).
Conclusions:
- There is no significant difference in the total time for airway management when using AuraGain™ versus i-gel™ for bronchoscopic intubation.
- While i-gel™ placement was faster, overall airway management time did not differ significantly between the two devices.
- Both devices facilitate oxygenation, but further research may explore factors influencing intubation success rates.
More Related Videos
04:30Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Acute Respiratory Failure-IV
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques