Related Experiment Video
Updated: Jul 26, 2026

Impact Assessment of Repeated Exposure of Organotypic 3D Bronchial and Nasal Tissue Culture Models to Whole Cigarette Smoke
Published on: February 12, 2015
Collection Tubes Can Cause False Elevations in Occupational and Clinical Evaluation of Antimony Exposure
Yifei K Yang1,2, Bryce Genesi2, Austin H Adams2
1Department of Pathology, School of Medicine, University of Utah, 201 Presidents' Circle, Salt Lake City, UT 84112, USA.
Abstract:
Occupational exposure to antimony has become rare in the past decades due to antimony mine closures and technological improvement in antimony processing plants in the USA. Although antimony's ubiquitous presence in plasticwares does not pose known health risk, it can present as a potential contaminant to antimony analysis for occupational exposure assessment. To understand the level of antimony contamination from plastic collection devices, we evaluated two different whole-blood plastic collection tubes that are routinely used for trace and toxic element assessment: royal blue BD Vacutainer® EDTA tube and Greiner VACUETTE® trace elements sodium heparin tube. We analyzed how different fill volumes may impact the concentrations of antimony detected. Although both collection tubes can introduce antimony contaminations to nitric acid and neutral buffer rinse, the Greiner heparin tube introduces a significantly lower amount of antimony to freshly collected whole-blood samples compared to the BD EDTA tube. When patients' samples are collected with BD EDTA tubes, they would exhibit elevated antimony concentrations that can be interpreted as potential antimony exposure. We conclude that the royal blue BD EDTA plastic tube is not suitable to evaluate blood antimony levels, and laboratories need to validate their own alternative sources when the glass tubes are not available.
More Related Videos
09:54Synthesis, Characterization, and Application of Superparamagnetic Iron Oxide Nanoprobes for Extrapulmonary Tuberculosis Detection
Published on: February 16, 2020
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pulmonary Tuberculosis I
Causative Organism
The primary infectious agent causing tuberculosis is Mycobacterium tuberculosis, a slow-growing, acid-fast, aerobic rod that exhibits sensitivity to heat and ultraviolet light. Instances of Mycobacterium bovis and Mycobacterium avium contributing to the development of TB infection are rare.
Mode of...
Pulmonary Tuberculosis III
The first classification is based on the development of the disease, and it includes the following categories:
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...