Related Experiment Video
Updated: Oct 4, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Diagnostic performance of digital breast tomosynthesis in female patients with nipple discharge
Sanja Barsic Ostojic1, Lora Grbanovic1, Ana Tonklin2
1Clinical Department of Diagnostic and Interventional Radiology, University Hospital Centre Zagreb, Zagreb, Croatia.
Background:
Nipple discharge is one of the most common symptoms related to the breast, but it is a presenting feature of breast cancer in 5%-12% of women.
Aims:
The purpose of this study was to determine the diagnostic performance of digital breast tomosynthesis (DBT) in the evaluation of patients with nipple discharge and to compare it with mammography (MMG), ultrasound (US), and magnetic resonance imaging (MRI).
Methods And Results:
This retrospective study included 53 patients with nipple discharge. All patients underwent DBT, and results were compared to MMG, breast US, and MRI. Radiological findings for each method were categorized according to BI-RADS classification: categories 1-2 were considered negative and categories 3-5 positive. If a tissue specimen was obtained, the final diagnosis was established based on the results of histopathological analysis; otherwise, a clinical follow-up was required for at least 2 years to confirm benign radiological findings. Measures of diagnostic accuracy of DBT, MMG, US, and MRI were calculated and compared.
Results:
Final histopathological analysis revealed six malignant breast lesions, all of which were detected in patients with pathologic nipple discharge. DBT and MRI exhibited high sensitivity (100%) and high negative predictive value (100%) for the detection of breast cancer in patients with nipple discharge. DBT showed higher specificity compared to MRI (82.9% vs. 61.9%). Sensitivity and specificity of MMG were 83.3% and 76.6%, respectively. Breast US was determined to have a sensitivity of 66.7% and specificity of 57.5%.
Conclusion:
DBT exhibited higher specificity than MRI at the same level of sensitivity and negative predictive value. Therefore, the use of DBT should be considered as an alternative to MRI in the assessment of patients with nipple discharge.
More Related Videos
13:35Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
13:43Intraductal Delivery and X-ray Visualization of Ethanol-Based Ablative Solution for Prevention and Local Treatment of Breast Cancer in Mouse Models
Published on: April 1, 2022