Organ dose from Varian XI and Varian OBI systems are clinically comparable for pelvic CBCT imaging
1Medical Physics Department, Waikato District Health Board, Hamilton, New Zealand. Luke.Gilling@waikatodhb.health.nz.
Abstract:
Pelvic cone-beam computed tomography (CBCT) occurs daily in many radiotherapy clinics as a part of image-guided verification before treatment. These images are acquired by the use of ionizing radiation. The dose received by CBCT imaging is often not quantified in a patient's radiation therapy prescription. The purpose of this work was to quantify the dose from a TrueBeam XI pelvic CBCT imaging system. The dose to organs from this imaging protocol was then compared with published dose data for OBI v1.4 pelvic CBCT imaging. A model of the Varian XI imager was constructed using GATE Monte Carlo scripting language. The model was calibrated by correlation with experimental measurements. An IBA 3D water tank was used to perform relative dose measurements in water. An adult anthropomorphic Alderson phantom with embedded thermolumeniscent dosimeters was used to evaluate dose from prostate CBCT imaging. Following the calibration, the GATE model was used to simulate the dose from the XI pelvic CBCT protocol to the ICRP computational anthropomorphic phantom. The Monte Carlo model constructed in GATE was validated for use in dose estimates for the XI pelvic imaging protocol. The D50 and D10 values tabulated the pelvic CBCT protocol show that doses to organs in the pelvic region are comparable for both systems. For a clinician who intends to evaluate the dose to organs as a result of CBCT imaging of the pelvis from the TrueBeam XI system, for the purposes of treatment planning, the doses reported for OBI v1.4 given in AAPM TG-180 provide a valid estimate.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...